NC Error Codes Diagnostics 80 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 42AE 17070 Function "The calculated end position differs from the end position in the nc instruction (internal error)." 42AF 17071 Parameter "Calculate remaining chord length" invalid value Value range: [0,1] 42B0 17072 Function "Set value generator SVB active" Starting the set value generator (SVB, SAF) has been refused, since the SVB task is already active. 42B1 17073 Parameter "SVB parameter not allowed" (INTERNAL ERROR) A parameter related to the internal structure of the set value generator (SVB) results in logical errors and/or to an FPU exception. Affects these parameters:
Minimum velocity (>0.0), TimeMode, ModeDyn, ModeGeo, StartType, DistanceToEnd, TBallRadius. 42B2 17074 Parameter "Velocity reduction factor not allowed" A parameter that controls reduction of the velocity at segment transitions is invalid. Parameter: 1. Transitions with continuous first differential: VeloVertexFactorC1 2. Not once continuously differentiable transitions: VeloVertexFactorC0, CriticalVertexAngleLow, CriticalVertexAngleHigh. 42B3 17075 Parameter "Helix is a circle" The helix has degenerated to a circle, and should be entered as such. 42B4 17076 Parameter "Helix is a straight line" The helix has degenerated to a straight line, and should be entered as such.
42B5 17077 Parameter "Guider parameter not allowed" One of the guider's parameters leads to logical errors and/or to an FPU exception. 42B6 17078 Address "Invalid segment address" (INTERNAL ERROR) The geometry segment does not have a valid geometry structure address or does not have a valid dynamic structure address. 42B7 17079 Parameter "Unparameterized generator" (INTERNAL ERROR) The SVB generator is not yet parameterized and is therefore unable to operate. 42B8 17080 Address "Unparameterized table" (INTERNAL ERROR) The table has no information concerning the address of the corresponding dynamic generator.
42BA 17082 Internal "The calculation of the arc length of the smoothed path failed (internal error)." 42BB 17083 Parameter "The radius of the tolerance ball is too small (smaller than 0.1 mm)." 42BC 17084 Internal Error while calculating DXD-Software-Limit switches (internal error) 42BD 17085 Function "NC-Block violates software limit switches of the group" At least one path axis with active software limit monitoring has violated the limit switches. Therefore the geometric entry is denied with an error.
42BE 17086 Parameter “Internal error in the evaluation of a possible software limit switch violation for the segment with the block- number xx.” At least one path axis with active position limit monitoring has violated the limit switches. 42BF 17087 Parameter Invalid reference speed type. 42C0 17088 Internal "Interpolating group contains axes of an incorrect axis type" An interpolating 3D group may only contain continuously guided axes of axis type 1 (SERVO). 42C1 17089 Internal "Scalar product cannot be calculated" The length of one of the given vectors is 0.0.