NC Error Codes Diagnostics 81 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 42C2 17090 Internal "Inverse cosine cannot be calculated" The length of one of the given vectors is 0.0. 42C3 17091 Parameter "Invalid table entry type" The given table entry type is unknown. 42C4 17092 Parameter "Invalid DIN66025 information type" (INTERNAL ERROR) The given DIN66025 information type is unknown. Known types: G0, G1, G2, G3, G17, G18, G19. 42C5 17093 Parameter "Invalid dimension" (INTERNAL ERROR) The CNC dimension is unknown. Known dimensions: 1, 2, 3. Or: The CNC dimension is invalid for the given geometrical object.
For a circle the dimension must be 2 or 3, while for a helix it must be 3. 42C6 17094 Parameter "Geometrical object is not a straight line" The given object, interpreted as a straight line, has a length of 0.0. 42C7 17095 Parameter "Geometrical object is not a circle" Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0 or a radius of 0.0. 42C8 17096 Parameter "Geometrical object is not a helix" Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0, or a radius of 0.0. or a height of 0.0.
42C9 17097 Parameter "Set velocity less than or equal to 0.0 is invalid" A value less than or equal to 0.0 for the set velocity (CNC) is not allowed, since the set velocity is positive by definition, and a set velocity of 0.0 cannot generate any motion. 42CA 17098 Address "Address for look-ahead invalid" (INTERNAL ERROR) The address supplied for the look-ahead is invalid. 42CB 17099 Function "Set value generator SAF active" Starting the set value generator (SAF) has been refused, since the SAF task is already active. 42CC 17100 Function "CNC set value generation not active" Stop or change of override refused, because the set value generation is not active.
42CD 17101 Function "CNC set value generation in the stop phase" Stop or change of override refused, because the set value generation is in the stop phase. 42CE 17102 Parameter "Override not allowed" An override of less than 0.0 % or more than 100.0 % is invalid. 42CF 17103 Address "Invalid table address" (INTERNAL ERROR) The table address given for the initialization of the set value generator is invalid, or no valid logger connection (report file) is present. 42D0 17104 Parameter "Invalid table entry type" The given table entry type is unknown. 42D1 17105 Memory "Memory allocation failed" Memory allocation for the table has failed.
42D2 17106 Memory "Memory allocation failed" Memory allocation for the filter has failed. 42D3 17107 Parameter "Invalid parameter" Filter parameter is not allowed. 42D4 17108 Function "Delete Distance To Go failed" Delete Distance to go (only interpolation) failed. This error occurred, if e.g. the command 'DelDTG' was not programmed in the actual movement of the nc program. 42D5 17109 Internal "The setpoint generator of the flying saw generates incompatible values (internal error)"