NC Error Codes 4.4 Axis Errors Diagnostics 84 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 42F8 17144 Parameter "Block search - segment not found" The segment specified as a parameter could not be found by the end of the NC program. Possible cause: • nBlockId is not specified in the mode described by eBlockSearchMode 42F9 17145 Parameter "Blocksearch – invalid remaining segment length" The remaining travel in the parameter fLength is incorrectly parameterized 42FB 17147 Internal Internal Error in the Context of Coupled Axes (Slave Axes) Fatal internal error using coupled axes (slave axes). Inconsistent internal state. Please, contact the support team.
42FC 17148 Parameter Parameter for the Maximum Number of Jobs (Entries) to be Transferred is Invalid The parameter that describes the maximum number of entries to transfer from the SVB to the SAF table per NC Cycle is invalid. Range of values: [1, 20] Unit: 1 42FF 17151 Monitoring Customer Specific Error In this connection it is about a customer specific monitoring function. Error(Hex) Error(Dec) Error type Description 4300 17152 Parameter "Axis ID not allowed" The value for the axis ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, is greater than 255, or does not exist in the current configuration. Value range: [1 ... 255] Unit:
1 4301 17153 Parameter "Axis type not allowed" The value for the axis type is not allowed, because it is not defined. Type 1: Servo Type 2: Fast/creep Type 3: Stepper motor Value range: [1 ... 3] Unit: 1 4306 17158 Parameter "Slow manual velocity not allowed" The value for the slow manual velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4307 17159 Parameter "Fast manual velocity not allowed" The value for the fast manual velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4308 17160 Parameter "High speed not allowed" The value for the high speed is not allowed. Value range: [0.0, 10000.0] Unit: e.g.
m/min 4309 17161 Parameter "Acceleration not allowed" The value for the axis acceleration is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s 430A 17162 Parameter "Deceleration not allowed" The value for the axis deceleration is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s