NC Error Codes Diagnostics 86 Version: 1.0 Error(Hex) Error(Dec) Error type Description 4316 17174 Parameter "Pulse time in positive direction not allowed" The value for the pulse width in positive direction is not allowed (pulsed operation). Value range: [0.0, 600.0] Unit: s 4317 17175 Parameter "Pulse time in negative direction not allowed" The value for the pulse width in negative direction is not allowed (pulsed operation). Value range: [0.0, 600.0] Unit: s 4318 17176 Parameter "Creep distance in positive direction not allowed" The value for the creep distance in positive direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g.
mm 4319 17177 Parameter "Creep distance in negative direction not allowed" The value for the creep distance in negative direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm 431A 17178 Parameter "Braking distance in positive direction not allowed" The value for the braking distance in positive direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm 431B 17179 Parameter "Braking distance in negative direction not allowed" The value for the braking distance in negative direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g.
mm 431C 17180 Parameter "Braking time in positive direction not allowed" The value for the braking time in positive direction is not allowed. Value range: [0.0, 60.0] Unit: s 431D 17181 Parameter "Braking time in negative direction not allowed" The value for the braking time in negative direction is not allowed. Value range: [0.0, 60.0] Unit: s 431E 17182 Parameter "Switching time from high to low speed not allowed" The value for the switching time from high to low speed is not allowed. Value range: [0.0, 60.0] Unit: s 431F 17183 Parameter "Creep distance for stop not allowed" The value for the creep distance for an explicit stop is not allowed. Value range: [0.0, 100000.0] Unit: e.g.
mm 4320 17184 Parameter "Motion monitoring time not allowed" The value for the motion monitoring time is not allowed. Value range: [0, 1] Unit: 1 4321 17185 Parameter "Position window monitoring not allowed" The value for the activation of the position window monitoring is not allowed. Value range: [0, 1] Unit: 1 4322 17186 Parameter "Target window monitoring not allowed" The value for the activation of target window monitoring is not allowed. Value range: [0, 1] Unit: 1 4323 17187 Parameter "Loop not allowed" The value for the activation of loop movement is not allowed. Value range: [0, 1] Unit: 1