NC Error Codes Diagnostics 94 Version: 1.0 Error(Hex) Error(Dec) Error Type Description Value range: [0, 1] Unit: 1 4422 17442 Function "Actual value setting is outside the value range" The "set actual value" function cannot be carried out, because the new actual position is outside the expected range of values. Value range: [-1000000.0, 1000000.0] Unit: e.g. mm 4423 17443 Parameter "Software end location minimum not allowed" The value for the software end location minimum is not allowed. Value range: [-1000000000.0, 1000000000.0] Unit: e.g. mm 4424 17444 Parameter "Software end location maximum not allowed" The value for the software end location maximum is not allowed. Value range:
[-1000000000.0, 1000000000.0] Unit: e.g. mm 4425 17445 Parameter „Filter mask for the raw data of the encoder is invalid“ The value for the filter mask of the encoder raw data in increments is invalid. Value range: [0, 0xFFFFFFFF] Unit: 1 4426 17446 Parameter „Reference mask for the raw data of the encoder is invalid“ The value for the reference mask (increments per encoder turn, absolute resolution) for the raw data of the encoder is invalid. E.g. this value is used for axis reference sequence (calibration) with the reference mode "Software Sync". Value range: [0x0000000F, 0xFFFFFFFF] Unit:
1 4427 17447 Parameter Parameter Dead Time Compensation Mode (Encoder) is Invalid The parameter for the mode of dead time compensation at the NC encoder is invalid (OFF, ON with velocity, ON with velocity and acceleration). Range of values: [0, 1, 2] Unit: 1 4428 17448 Parameter Parameter “Control Bits of Dead Time Compensation” (Encoder) is Invalid The parameter for the control bits of dead time compensation at the encoder is invalid (e.g. relative or absolute time interpretation). Range of values: [>0] Unit:
1 4429 17449 Parameter Parameter “Time Related Shift of Dead Time Compensation Mode” (Encoder) is Invalid The parameter for time related shift of dead time compensation (time shift in nanoseconds) at the encoder is invalid. Range of values: [-1.0E9 .. 1.0E9] Unit: ns 4430 17456 Function "Hardware latch activation (encoder)" Activation of the encoder hardware latch was implicitly initiated by the referencing procedure. If this function has already been activated but a latch value has not yet become valid ("latch valid"), another call to the function is refused with this error.
4431 17457 Function "External hardware latch activation (encoder)" The activation of the external hardware latch (only available on the KL5101) is initiated explicitly by an ADS command (called from the PLC program of the Visual Basic interface). If this function has already been activated, but the latch value has not yet been made valid by an external signal ("external latch valid"), another call to the function is refused with this error.