Delta AH500 — 6.4.2 Explanation of Data Transfer Instructions

Chapter 6 Applied Instructions Additional remark: 1. Suppose the data involved in the instruction is binary-coded decimal numbers. If the number in S is not within the range between 0 and 9999, or if the number in D is not within the range between 0 and 9999, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200D. 2. If m 1 is less than 1, or if m 1 is larger than 4, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B. 3. If m 2 is less than 1, or if m 2 is larger than m 1 , the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B. 4.

If n is less than m 2 , or if n is larger than 4, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B. 6-133