Chapter 6 Applied Instructions Symbol S 1 : Timer number S 2 : Setting value of the timer Explanation Refer to the explanation of the TMRH instruction (API 1002) for details. 6_ 6-263 API Instruction code Operand Function 1001 TMR S , S 1 2 16-bit timer (100ms) Device X Y M S T C HC D FR SM SR E K 16# “$” F S 1 S 2 BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S 1 S 2 Pulse instruction 16-bit instruction 32-bit instruction - AS -