Delta Electronics — 2.2.7 Special Auxiliary Relays (SM)

AS Series Programming Manual _2 2-42 AS300 Series AS200 Series Latched Attribute Default OFF STOP RUN SM Function    ON RUN STOP SM1437 Error in data exchange connection 30 through EtherNet/IP (Scanner) ○ – OFF – – N R OFF SM1438 Error in data exchange connection 31 through EtherNet/IP (Scanner) ○ – OFF – – N R OFF SM1439 Error in data exchange connection 32 through EtherNet/IP (Scanner) ○ – OFF – – N R OFF SM1440 Error in I/O connection 1 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1441 Error in I/O connection 2 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1442 Error in I/O connection 3 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1443 Error in I/O connection 4 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1444 Error in I/O connection 5 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1445 Error in I/O connection 6 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1446 Error in I/O connection 7 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1447 Error in I/O connection 8 through EtherNet/IP (Adapter) ○ ○ OFF - - N R OFF SM1581 Refresh and then release the control over the connection of Delta servo CAN axis 1 ○ ○ OFF OFF – N R/W OFF SM1582 Refresh and then release the control over the connection of Delta servo CAN axis 2 ○ ○ OFF OFF – N R/W OFF SM1583 Refresh and then release the control over the connection of Delta servo CAN axis 3 ○ ○ OFF OFF – N R/W OFF SM1584 Refresh and then release the control over the connection of Delta servo CAN axis 4 ○ ○ OFF OFF – N R/W OFF SM1585 Refresh and then release the control over the connection of Delta servo CAN axis 5 ○ ○ OFF OFF – N R/W OFF SM1586 Refresh and then release the control over the connection of Delta servo CAN axis 6 ○ ○ OFF OFF – N R/W OFF SM1587 Refresh and then release the control over the connection of Delta servo CAN axis 7 ○ ○ OFF OFF – N R/W OFF SM1588 Refresh and then release the control over the connection of Delta servo CAN axis 8 ○ ○ OFF OFF – N R/W OFF SM1601 Refresh and then release the control over the connection of Delta motor CAN axis 21 ○ ○ OFF OFF – N R/W OFF SM1602 Refresh and then release the control over the connection of Delta motor CAN axis 22 ○ ○ OFF OFF – N R/W OFF SM1603 Refresh and then release the control over the connection of Delta motor CAN axis 23 ○ ○ OFF OFF – N R/W OFF SM1604 Refresh and then release the control over the connection of Delta motor CAN axis 24 ○ ○ OFF OFF – N R/W OFF SM1605 Refresh and then release the control over the connection of Delta motor CAN axis 25 ○ ○ OFF OFF – N R/W OFF SM1606 Refresh and then release the control over the connection of Delta motor CAN axis 26 ○ ○ OFF OFF – N R/W OFF SM1607 Refresh and then release the control over the connection of Delta motor CAN axis 27 ○ ○ OFF OFF – N R/W OFF SM1608 Refresh and then release the control over the connection of Delta motor CAN axis 28 ○ ○ OFF OFF – N R/W OFF