Delta Electronics — 6.17.2 Explanation of Real-time Clock Instructions

AS Series Programming Manual Example 2 Set the DST to start on 1 st April and to end on 3 rd September and the duration is 60 minutes. Enable DST function and read the DST state. _6 Setting values and descriptions: Enable contact M0 Y0.0=ON, indicating DST function is enabled. The PLC system time adds 60 minutes when the date April 1st arrives, and subtracts 60 minutes when the date September 3rd arrives to end daylight saving time. 6-514 D112 X Invalid operand D120 X Invalid operand Y0.1 OFF Node state is OFF. Device Setting Value Description D0 1 The DST state is ON and in mode 1. D1 4 Starting month: April D2 1 Starting date: the 1st D11 9 Ending month: September D12 3 Ending date:

the 3rd D20 60 Duration: 60 minutes