Delta Electronics — 6.18.2 Explanation of Peripheral Instructions

Chapter 6 Applied Instructions 5. The wiring: 1 2 4 8 10 0 10 1 10 2 10 3 24VDC + 10 3 10 2 10 1 10 0 10 3 10 2 10 1 10 0 V+ 1 2 4 8 V+ 1 2 4 8 First 7-segment display Second 7-segment display Note: The transistor output module AH16AN01T-5A is used in this example. Additional remarks  Whether an output is a positive output or a negative output, and whether there is one four-digit seven-segment display or two four-digit seven-segment displays depend on n .  The outputs on the PLC should be NPN transistors whose collectors are open collectors. In addition, an output has to connect a pull-up resistor to the DC power supply (less than 30 VDC).

Therefore, when an output is ON, a signal of low potential is output.  The following table shows the negative logic. 6_ 6-537 Y0.0 Y0.1 Y0.2 Y0.3 Y0.4 Y0.5 Y0.6 Y0.7 Y0.8 Y0.9 Y0.10 Y0.11 UP ZP Binary-coded decimal value Output Signal (Binary-coded decimal code) b3 b2 b1 b0 8 4 2 1 A B C D 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 1 0 0 0 1 1 1 1 0 0 0 1 0 0 0 1 0 1 1 0 1 0 0 1 1 0 0 1 1 1 1 0 0 0 1 0 0 0 1 0 0 1 0 1 1 0 1 0 1 0 1 0 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 0 1 0 1 1 1 0 1 1 1 1 0 0 0 1 0 0 0 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 0 1 1 0