Robot Diagnostics ACE User's Guide, 3.6.x 18316-000 Rev A Page 1114 Item Description Output Level Specifies a commanded torque, which is used to test the operation of the selected motor. The range is from -32767 to 32767, or the range specified by the “Max Output Level" parameter for that motor in the Robot Editor. Position Displays the current position (in encoder counts) of the selected motor. Pos Error Displays the position error (in encoder counts) of the selected motor. Index Delta Displays the change (in encoder counts) from the previous latched zero index and the most recent latched zero index of the selected motor.
Note that this is only useful with incremental encoders, to verify zero index spacing and proper encoder readings. Error Displays the errors for the selected motor, as follows: P Positive overtravel N Negative overtravel D Duty cycle error A Amp fault R RSC power failure E Encoder fault H Hard envelope error S Soft envelope error M Motor stalled Status Displays the status of the selected motor, as follows: P High power on T In tolerance C Calibrated H Home (sensor) active V V+ control I Independent control Q Current mode P Position mode W Square wave active S Servo trajectory active Reset Resets any encoder errors for the selected motor.
Power Toggles the high power (the status field displays the current power