omron — Process Strategies

Process Strategies ACE User's Guide, 3.6.x 18316-000 Rev A Page 884 Item Description ition for" time (in milliseconds) while waiting for a part or target to process. For example, if the "After waiting for" time is 500 ms, when there is a break in the part or part target processing queue, the robot will move to the idle position after 500 ms (1/2 sec). Use Custom Wait Program Allows you to specify a custom V+ wait program. The program would be called when the robot does not have a part or target available. The program could check to see if the robot needs to be moved to the idle location or if it should stay at the current location. NOTE:

This program starts with the logic specified by one of the selections above. If this option is selected, a wizard guides you through the program-creation pro- cess. For details, see Process Strategies on page 878. Use Signal at Cycle Stop When a cycle stop is issued and this option is enabled, the specified I/O signal will be turned on when the robot has reached the cycle stop state. When the cycle is resumed (cycle stop state is canceled), it will turn the specified signal off and will attempt to enable power, if high power was disabled. For more details on cycle stop, see Process Manager Control on page 920. Error Responses:

Output Signal - On Error Defines a digital signal to assert when an error is detected for the selected robot. Error Listing Specifies how specific error conditions are to be handled. By default, all errors will be reported to the user and the software will wait until the user responds to the error. If an error condition is defined, it will override this default error hand- ling. It can be used to define automatically handling of these kinds of errors:

Single Error CodeError code defined by user Range of Error CodesError code range defined by user Belt Window Access ErrorBelt window violations Robot Power ErrorsProblems with power being enabled or enabling power Gripper ErrorsAll gripper actuations All ErrorsAll other errors. When an error is detected for the robot, it will process the error listing handlers defined by the user and find the first one that can handle the condition. If the error cannot be handled by an item in the list, the error is reported to the user.