Komatsu — Re-charging a built-in battery

5 Maintenance Re-charging a built-in battery Disconnect the cable of the negative pole before re-charging or pull the battery main switch, in order to interrupt the power supply. Otherwise, the alternator is damaged due to high volt­ age peaks. Remove all battery plugs before re-charging to ensure suffi­ cient ventilation. To prevent gas explosions, do not come near the battery with fire and do not produce any sparks. Interrupt the charging process if the temperature of the bat­ tery acid exceeds 45° C. Switch off the battery charger, as soon as the battery is re- charged. If the battery is overloaded, the following situations may occur:

The battery may be overheated Decrease in the battery acid volume Damage of the electrode plates. Do not mix up the cables (positive (+) and negative (-) Before performing maintenance operations, remove all cables from the battery poles. Only exceptions: acid level check or the measurement of the specific density. 5-36 WA90-5 – VEAM270100