OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Menu Control with Key Switch (C) and Key Group (D). Display of DIGITAL-OUTPUTS Example: You want to display the setting of the Central Lubrica- tion System Relay K29 in the group *DIGITAL-OUTPUTS*, starting from menu level -2-, see Menu Control Chart IV. Proceed as follows: 1. Starting from level-2- *ANALOG-INPUTS* press key (12) twice, the display changes to *DIGITAL-OUTPUTS*: 2. Press ”QUI” key (10) the starting menu item ”H22 ACOUSTIC SIGNAL* in level -3- appears on the display, see chart IV. 3. Press key (12) until the menu item *K29 RELAY CLS PUMP ON* is displayed. 4. Press key (10).
Depending on the Operating Condition of the Central Lubrica- tion System one of the two following displays (A or B) in level -4- appears on the screen: A Display with Central Lubrication Pump ON (Lubrication Cycle). - 4 - Relay CLS pump ON 0 1 K29 (A5.7): 1 B Display with Central Lubrication Pump OFF - 4 - Relay CLS pump OFF 0 1 K29 (A5.7): 0 5. For display of further Relay settings go back to level -3- by pressing ”RET” key (9). 6. Use key (12 or 11) to select those relays you want to be dis- played. 7. Press key (10) for display of relay setting in level -4-. 8. For returning to the basic display in level -0- press key (9) four times.
DO NOT change any settings in the INPUT-OUTPUT groups before having the permission of authorized Service Person- nel. Refer to the ECS Service Manual for more information. 131 CAUTION