Komatsu — 4.14.1 SWING GEARS AND MOTOR ADAPTER HOUSING - CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR Motor Adapter Housing, Change Oil: 1. Remove level gauge (4) and breather filter (5). Insert the hose of a suction pump into the gauge pipe (4) until the hose end just touches the bottom of the T-union. Place the oil outlet hose of the suction pump into a receptacle. Switch on the pump and completely suck off the oil from the motor housing. If a suction pump is not available, place a receptacle below drain plug (6). Remove plug (6) and drain the oil completely. 2. Clean breather filter (5) with compressed air from inside to outside and re-install. 3.

If removed, install drain plug (6) and fill-up gear oil through filler opening (4), up to the "MAX" mark on level gauge (4) and install the level gauge. 4. After short operating period check oil level and housing for leaks. 455