UPPERSTRUCTURE / Pump Device 7. Install bracket (44) to the main frame with bolts (45) (5 used). : 90 N m (9.2 kgf m, 66 lbf ft) : 19 mm 32 45 W1J1-02-04-045 Main Frame CAUTION: Air cleaner (38) weight: 35 kg (77 lb) 8. Apply LOCTITE #262 to bolts (45) (4 used). Attach a nylon sling onto air cleaner (38). Hoist and move air cleaner (38) to the mounting position for bracket (44). Install air cleaner (43) to bracket (32) with bolts (45) (4 used). 43 32 : 17 mm : 50 N m (5.1 kgf m, 37 lbf ft) NOTE: Install bolts (45) (4 used) through the bolt mounting hole at pump space side. W1J1-02-04-044 45 32 Bolt Mounting Hole W1J1-02-04-043 W2-4-9