hitachi — ASSEMBLE CONTROL VALVE (HOUSING FRONT AND REAR SURFACES)

UPPERSTRUCTURE / Control Valve Assemble Control Valve (Housing Front and Rear Surfaces) 1. Install O-ring and backup ring (5) to cap (6). Install check valve (3), spring (4) and cap (6) to housing (2). : 14 mm : 350 N m (36 kgf m, 258 lbf ft) W2-5-67