Yanmar — Yanmar BY Series Engine Electronic Control System Operation Manual

Appendix D Yanmar BY Unlimited Default Settings: Dual Engine For stern drive configuration, the engine interface part number is i8130. For marine gear the part number is i8140.

Stern Drive Engine Interface part number i8130P i8130S Idle RPM not adjustable not adjustable Sync Cruise Cruise Lead Engine Port* Port* Split Range Throttle 25% 25% Forward Throttle Curve F1 F1 Reverse Throttle Curve R1 R1 Programmable Shift Delay 4.8 4.8 Fixed Shift Delay 0 0 Station Select Protection Off Off Marine Gear Engine Interface part number i8140P i8140S Idle RPM not adjustable not adjustable Sync Cruise Cruise Lead Engine Port* Port* Troll Trans Type ZF ZF Troll Engage RPM 800 800 Split Range Throttle 25% 25% Forward Throttle Curve F1 F1 Reverse Throttle Curve R1 R1 Programmable Shift Delay 4.8 4.8 Fixed Shift Delay 0 0 Station Select Protection Off Off Troll Mode** Full Full Troll Lever Travel 60% 60% Maximum Throttle in Troll Mode 40% 40% Troll Throttle Engage Delay 0.2 0.2 Note:

A system reset may be needed for some changes to take effect. *Only shows when Sync is set to Power Train **Troll Mode functions are not displayed until Troll Mode is selected. Electronic Control System: Operation Manual for BY Series Engines with Unlimited Controls Page 24 © Yanmar 2008