. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER (KOMTRAX Plus BUILT-IN TYPE) EXTERNAL DISPLAY LAMPS CAUTION HD605-7 1 31.5 tons and up 2 56.7 tons and up 3 63.0 tons and up If the red lamp lights, the machine is overloaded. PREDICTED LOAD DISPLAY When the load changes in steps for each bucket loaded, the system estimates the total payload if one more bucket is loaded, payload meter estimates the predicted load and display the predicted load by flashing the lamp. When red lamp flashed, next load will carry over loading. The predicted load display and actual payload display are shown at the same time. [Example: Case of HD465, expected number of bucket loads:
4] 1st bucket 11 tons 2nd bucket 11 tons (total: 22 tons) 3rd bucket 11 tons (total: 33 tons) 4th bucket 11 tons (total: 44 tons) When the machine is loaded in this way, the external display lamps light up as shown in the chart below. 6 - 25 the re d lamp lights up, the machine is overloaded. If the machine carries an excessive load, the machine will be damag ed. To revent overloading, continue loading until the yellow lamp lights up. If the red lamp flashes, stop loading The external lamps display the payloa d as follows Color of lamp HD465-7 Green 23.0 tons and up Yellow 41.4 tons and up Red 48.3 tons and up