hitachi — REGULATOR FOR FAN PUMP

COMPONENT OPERATION / Pump Device Link Mechanism The movement of pilot piston (22) is transmitted through pin (21) to lever 1 (18). Lever 1 (18) is turned about pin (19), which is fixed to the axial plug. The movement of pilot piston (11) is transmitted through pin (12) to lever 2 (4). Lever 2 (4) is turned about pin (5), which is fixed to the hous- ing. Pin (7) is attached to feedback lever (13). Both ends of pin (7) are inserted into holes (23, 8) on lever 1 (18) and lever 2 (4). Therefore, when lever 1 (18) or lever 2 (4) turns, pin (7) contacts the hole of the turned lever. Feedback lever (13) turns about pin (14) at- tached to servo piston (15).

In addition, when servo piston (15) moves, feed- back lever (13) is moved through pin (14). At this time, as neither lever 1 (18) nor lever 2 (4) move, feedback lever (13) turns about pin (7). Axial Plug T1J1-03-01-007 2 - Spool 7 - Pin 13 - Feedback Lever 19 - Pin 4 - Lever 2 8 - Hole 14 - Pin 21 - Pin 5 - Pin 11 - Compensating Rod 15 - Servo Piston 22 - Pilot Piston 6 - Pin 12 - Pin 18 - Lever 1 23 - Hole T3-1-14 Housing 5 NOTE : Displacement A 12 4 : Displacement A 8 11 13 6 7 18 23 19 2 21 14 22 15 4 8 18 23