hyundai — HX220SL

3. CHARGING CIRCUIT 3. CHARGING CIRCUIT When the starter is activated and the engine is started, the operator releases the start switch to the ON position. Charging current generated by operating alternator flows into the battery through the battery relay [CR-1]. The current also flows from alternator to each electrical component and controller through the fuse box.

1) OPERATING FLOW OPERATING FLOW (1) Warning flow Warning flow Alternator [CN-74 (2)] I/conn [CN-1 (9)] United MCU alternator voltage [CN-52 (27)] Cluster charging warning lamp (Via CANbus interface) Charging flow Charging flow Alternator [CN-74 (B + )] Battery relay(M8) (2) Battery (+) terminal Circuit breaker [CN-60] Master switch [CS-74A] Fuse box [No.3~8] Circuit breaker [CN-95] Fuse box [No.16~34] Air compressor power [CN-258 (1)] 2) CHECK POINT 侍 GND : Ground 4-10 Engine Start switch Check point Voltage RUN ON 刮 - GND (battery voltage) 刯 - GND (battery relay) + 到 - GND (alternator B terminal) 刱 - GND (alternator 2 terminal) 刲 - GND (United MCU) 20~25V