Deutz — 2.3.2 CONNECTION TO THE INFOCENTER

2. CONNECTING THE TESTER TO THE ELECTRONIC 2.3 CONNECTING THE PORTABLE COMPUTER WITH 2.3 CONNECTING THE PORTABLE COMPUTER WITH “EDS” SOFTWARE TO THE TRANSMISSION CONTROL UNIT AND INFOCENTER 2 6 4 3 5 1 F0059430 2.3.1 CONNECTION TO THE TRANSMISSION CONTROL UNIT 1 - Connect the lead numbered “9141” of the interface cable (1) to the serial port of the portable computer (2). 2 - Join the connector marked “Powershift Agrotron 4.70 – 6.45” (3) of the Wilbar cable (4) (Wilbar KA 96-0529) to the four-pin connector (5) of the interface cable (1). 3 - Join the connector (6) of cable (4) to the connector X18 located internally of the right hand side console.

4 - With the portable computer switched on and the EDS program running, insert the starter key and turn to the “ I ” (ON) position. 2.3.2 CONNECTION TO THE INFOCENTER 1 - Connect the lead marked “EIC” of the interface cable (1) to the serial port of the portable computer (2). 2 - Join the connector marked “Infocenter” (3) of the Wilbar cable (4) (Wilbar KA 96-0529) to the two-pin connector (7) of the interface cable (1). 3 - Join the connector (6) of cable (4) to the connector X18 located internally of the right hand side console. 4 - With the portable computer switched on and the EDS program running, insert the starter key and turn to the “ I ” (ON) position. 20-11