Komatsu PC160-6K, PC180LC-6K, PC180NLC-6K, PC200EN-6K, PC200EL-6K — Komatsu PC160-6K, PC180LC-6K, PC180NLC-6K, PC200EN-6K, PC200EL-6K User Manual

24. SERVICE PROCEDURE Caution: When using the starting motor to vent the system, do not engage it for more than 30 seconds at a time: Wait two (2) minutes between engagements. Warning: It is necessary to put the engine in the “Run” position. Because the engine may start, be sure to follow all the safety pre- cautions. Use the normal engine starting procedure. High pressure Lines Venting Warning: The pressure of the fuel in the line is sufficient to penetrate the skin and cause serious bodily harm. 1. Loosen the fittings at het injectors, and crank the engine to allow entrapped air to bleed from the lines. Tighten the fittings. Re- Tighten Line Fittings Torque Value:

30 Nem [22 ft-lb] Warning: Do not bleed a hot engine as this could cause fuel to spill onto a hot exhaust manifold creating a danger of fire. 2. Start the engine and vent one line at a time until the engine runs smoothly. iy. ' . co! PC160/180/200-6k-ENG <—— AD|. STs pean pet Shh | tLse RAN. oiStbua 3-63