Section 6 - Injectors and Fuel Lines - Group 06 Injectors - Rebuild (6-02) M11 Page 6-5 Visually inspect the orifice screen for damage, contami- nation or metal particles. If damaged or contaminated parts are found, the injectors must be replaced. NOTE: Some CELECT™injectors do not contain an orifice screen. Injectors - Rebuild (6-02) CELECT™injectors cannot presently be rebuilt. They must be replaced with new injectors. Injectors - Calibration (6-03) NOTE: CELECT™injectors do not require flow calibration. The CPL (Control Parts List) Manual, Bulletin No. 3379133 is a listing of basic engine parts and static timing speci- fications which are necessary to produce a given engine performance.
The CPL number stamped on the engine dataplate is used to identify parts within the engine, in- cluding the injectors.