10 Fieldwork settings 10.5 Cleaning unit 67086 10.5 Cleaning unit 87656 10.5.1 Checking / adjusting the fan speed display When delivered ex works, the fan speed display is acti- vated. The display must be checked / pre-set as required or after carrying out installation work on the fan drive. 1 S Set fan speed to the lowest value with crank (1). Observe the general warnings at the beginning of the "Fieldwork settings" chapter. Loosen clamp (3) and adjust plastic indicator rod (2) so that the coloured ring is on the lowest number of indicator scale (4).
14 19634 2 3 19635 15 82695 10.5.2 Adjusting the cleaning performance monitor sensors The cleaning and separation performance monitor allows the operator to make full use of the capacity of the machine. A display allows the operator to determine how fast the machine can be driven without the reasonable grain loss limit being exceeded. 2 The grains carried beyond the sieve pan fall onto the sensor (2). The pulses generated are visualised by meter lights on a display. The sensor (2) reacts with different sensitivities to dif- ferent grain sizes and must therefore be calibrated to the respective grain size, using switch (4).
16 19648 The sensitivity setting of the display is carried out while fieldwork is in progress. See Adjusting the cleaning performance monitor display. 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09 181