26. HANDLING PAYLOAD METER 26.3 OPERATING PAYLOAD METER Resetting power (the power can be reset by turning the power ON.) The display for the first 3 seconds is 88:88, and after that, the time is displayed for 7 seconds. After 10 seconds, the normal display is given. The printer feeds one line of paper and stops at the home position. 26.3.1 CONTENT OF DISPLAY When the dump lever is at FLOAT and the shift lever is at neutral, the actual load is displayed. When the load is less than 3.9 tons, or if the dump lever is not at FLOAT, the display is 0. If the dump lever is at FLOAT but the shift lever is not at neutral, the time display is given.
A maximum of 200 cycles of data can be written to memory. If this level is exceeded, FULL is displayed. If FULL is displayed, print out the data and clear the data from the memory. For details, see “DELETING DATA FROM MEMORY”. After completion of operations, we recommend that you stop the machine, print out the data, and clear the data from memory. There may be a slight change between the load displayed at the loading point and the load displayed at the dumping point. Save the data to memory when the dump lever is raised. When the machine is completely stopped, it is possible to carry out accurate calculation if the load is dumped when the swaying of the machine has completely stopped.
We recommend that the slope at the dumping point be kept to within±5°. When the value displayed by the payload meter becomes stable, move the dump lever to the RAISE position. If the machine is still swaying violently when the dump lever is moved to the RAISE posi tion, ***** is printed when the print out is made. When the dump lever is returned from LOWER to FLOAT, wait for at least 5 seconds before turning the starting switch OFF. 5-5