TM2361 (24JUN08) 9015-15-22 450DLC Excavator Operation and Tests 062608 PN=466 Sub-System Diagnostics Engine Speed Dial and ECO Control: When the engine P Mode—At this position, the power mode switch speed dial is rotated clockwise or counterclockwise, (S12) does not provide ground to terminals B6 and the speed dial sends a corresponding signal that B14. When the MCF detects no ground at both represents the target speed to terminal D15 on the terminals, the MCF sends a signal to the ECM MCF and terminal C4 of the monitor controller.

The (through the CAN data link) to control the engine MCF then sends a corresponding signal through the speed from slow to fast idle in response to the position CAN data link to the ECM. The ECM compares this of the engine speed dial. information with inputs from ECM sensors and increases or decreases the actual engine speed HP Mode—At this position, the power mode switch accordingly. (S12) provides a ground to terminal B14 on the MCF. When the MCF detects this ground, the MCF sends a NOTE:

The voltage signal at terminal C4 of the signal to the ECM (through the CAN data link) to monitor controller can be viewed on the increase engine speed approximately 100 rpm more monitor display by accessing the Data Items than the target speed (as set by the engine speed dial) Menu on the monitor controller. when digging power is needed. The engine speed control has a function called the The MCF will send a signal to the ECM to increase ECO. When the engine speed is more than 1600 rpm actual engine speed more than the target speed when and the pressure sensor inputs to the MCF indicate the following conditions occur:

that all hydraulic control levers are in the neutral position for a minimum of 1 second, the MCF sends a • Power mode switch at HP position. 9015 15 22 signal to the ECM to reduce engine speed to 1600 • Engine speed dial set to target speed of 1020 rpm rpm. or higher. • MCF detects pressure as sensed by boom up NOTE: When target speed set by the engine speed pressure sensor (B52) (terminal C13) and/or arm in dial is less than 1600 rpm and hydraulic pressure sensor (B51) (terminal C23). controls are not actuated for at least 1 second, • MCF detects high average pressure as sensed by the actual engine speed will remain pump 1 delivery pressure sensor (B35) (terminal C3) unchanged.

and pump 2 delivery pressure sensor (B37) (terminal C12). Power Mode Control: The power mode control consists of the following functions: A/I (Auto-Idle) Mode: The auto-idle feature reduces engine speed when hydraulic functions are not being • E Mode (Economy) operated for more that 4 seconds. • P Mode (Standard) • HP Mode (High Power) When the auto-idle switch (S8) is turned to the A/I position, the switch connects terminal B18 on monitor E Mode—At this position, the power mode switch controller (A4) to ground. When the monitor controller (S12) provides a ground to terminal B6 on the MCF.

detects ground at terminal B18, the auto-idle indicator When the MCF detects this ground, the MCF sends a will appear on the monitor display. The auto-idle switch signal to the ECM (through the CAN data link) to limit also connects MCF terminal B13 to ground to inform the engine target speed to a maximum of 1580 rpm. the MCF that auto-idle mode has been selected. The E mode function also reduces load on the engine by reducing the flow rate of main pumps 1 and 2 by 15 percent. For more information, see Pump Control—E Mode later in this theory of operation. Continued on next page CS33148,00008EB –19–28APR06–5/15