TM2361 (24JUN08) 9015-15-38 450DLC Excavator Operation and Tests 062608 PN=482 Sub-System Diagnostics The windshield wiper and washer circuit has four respectively, to windshield wiper and washer switch modes of operation: (S9). When the windshield wiper and washer switch is turned to INT or ON position, the switch sends a • Windshield wiper ON (continuous) voltage to terminal C3 of the monitor controller. The • Windshield wiper INT (intermittent) position of the switch dictates the strength of the • Windshield wiper OFF (park) voltage. The monitor controller measures the voltage, • Windshield wash then provides the appropriate ground (intermittent or continuous) at terminals A2 and A11.
Operation of the windshield wiper and washer circuit is controlled by signals from monitor controller (A4) and Windshield Wiper Continuous Operation—When the position of the wiper motor internal status switch. windshield wiper and washer switch (S9) is turned to the ON position, the switch sends approximately 4.85 The operation of the wiper motor internal status switch volts to terminal C3 of the monitor controller. When the is as follows: monitor controller receives this level of voltage at terminal C3, it will connect terminals A2 and A11 to • Wiper at PARK position:
Internal status switch ground, and thus provide a ground for the coil of connects wiper motor terminal S to wiper motor windshield wiper relay (K6). In this mode of operation, terminal B. the monitor controller provides a continuous ground, • Wiper NOT at PARK position: Internal status switch thus causing the relay to stay energized. connects wiper motor terminal S to ground.
With the windshield wiper relay energized, the ground 9015 15 38 When key switch (S1) is turned to the ON position, at terminal 3 of the relay is connected to terminal L of power from windshield wiper and washer 10 amp fuse the wiper motor, activating the wiper motor, causing (F2) becomes available at the following components: the wiper blade to move back and forth continuously across the windshield.
• Windshield wiper motor (M5) (terminal B) • Windshield wiper relay (K6) (terminal 1) Windshield Wiper Intermittent Operation—When the • Windshield washer relay (K9) (terminals 1 and 3) windshield wiper and washer switch is turned to one of the three INT (intermittent) positions (slow/middle/fast), When windshield wiper and washer switch (S9) is in the switch will send a specific voltage between the OFF position, no voltage is present at terminal C3 approximately 1.5 and 3.5 volts to terminal C3 of the of the monitor controller. When the monitor controller monitor controller.
When the monitor controller detects no voltage at terminal C3, the monitor will not receives the specified voltage, it will connect terminals connect terminals A2 and A11 to ground, and thus A2 and A11 to ground for approximately one second. windshield wiper relay (K6) stays de-energized. With This gives the wiper motor enough time to move off the windshield wiper relay de-energized and the wiper the PARK position, whereas, the internal status switch assembly at the PARK position, power is routed from takes over providing the ground for the wiper motor.
the wiper motor terminal B, through the internal status The wiper motor completes one full cycle and returns switch, out terminal S of the windshield wiper motor to the PARK position. The wiper motor stays at the (M5), across the normally closed contacts (terminals 3 PARK position until the windshield wiper relay receives and 4) of the windshield wiper relay, then back to the the next ground pulse from the monitor controller. wiper motor at terminal L. This puts both sides of the wiper motor at the same voltage potential, ensuring the In this mode of operation, the monitor controller sets wiper motor does not operate until when needed.
the amount of time delay by the amount of voltage detected at terminal C3, The time delay versus voltage The monitor controller (A4) provides a 5-volt reference at terminal C3 is as follows: voltage and a signal ground out terminals C6 and C9, Continued on next page LD30992,0000215 –19–27APR06–2/3