TM2361 (24JUN08) 9015-20-46 450DLC Excavator Operation and Tests 062608 PN=536 References Item Data Unit Min. Adjustment Value Adjustable Range Standard Adjustment ATT1 ATT1 ATT Type Attachment selection BR, PU, CR, VI, Un, Non — BR, PU, CR, VI, Un, Non BR ATT1 ATT No.
Attachment setting number selection 1, 2, 3, 4, 5 — 1 to 5 1 ATT1 P1 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 1 flow rate L/min 0.5 L/min 100—367 L/min 367 L/min when using attachment ATT1 P2 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 2 flow rate L/min 0.5 L/min 100—367 L/min 200 L/min when using attachment ATT1 Engine Speed Increase/Decrease Adjustment of engine speed when using attachment min-1 10 min-1 -500—100 min-1 0 min-1 ATT1 Secondary Pilot Relief Pressure Secondary pilot relief valve ON/OFF ON, OFF — ON/OFF Unregistered Selection selection ATT1 Selector Valve Selector valve ON, OFF — C/V or 0/T Unregistered Selection ON/OFF selection ATT1 Accumulator Accumulator ON/OFF ON, OFF — ON/OFF Unregistered Selection selection ATT1 2-Speed 2-Speed selection ON, OFF — ON/OFF Off Selection ON/OFF selection ATT2 ATT2 ATT Type Attachment selection BR, PU, CR, VI, Un, — BR, PU, CR, VI, Un, BR Non Non ATT2 ATT No.
Attachment setting 1, 2, 3, 4, 5 — 1 to 5 2 number selection ATT2 P1 Max Swash Adjustment of lower L/min 0.5 L/min 100—367 L/min 367 L/min Angle Adjustment limit of maximum pump 1 flow rate when using attachment ATT2 P2 Max Swash Adjustment of lower L/min 0.5 L/min 100—367 L/min 250 L/min Angle Adjustment limit of maximum pump 2 flow rate when using attachment ATT2 Engine Speed Adjustment of engine min-1 10 min-1 -500—100 min-1 0 min-1 Increase/Decrease speed when using attachment Continued on next page LD30992,0000220 –19–25APR06–25/30 Selection selection 9015 20 46 ATT1 Selector Valve Selection Selector valve ON/OFF selection ON, OFF — C/V or 0/T Unregistered ATT1 Accumulator Selection Accumulator ON/OFF selection ON, OFF — ON/OFF Unregistered ATT1 2-Speed Selection 2-Speed selection ON/OFF selection ON, OFF — ON/OFF Off ATT2 ATT2 ATT Type Attachment selection BR, PU, CR, VI, Un, Non — BR, PU, CR, VI, Un, Non BR ATT2 ATT No.
Attachment setting number selection 1, 2, 3, 4, 5 — 1 to 5 2 ATT2 P1 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 1 flow rate when using attachment L/min 0.5 L/min 100—367 L/min 367 L/min ATT2 P2 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 2 flow rate when using attachment L/min 0.5 L/min 100—367 L/min 250 L/min ATT2 Engine Speed Increase/Decrease Adjustment of engine speed when using attachment min-1 10 min-1 -500—100 min-1 0 min-1