TM2361 (24JUN08) 9025-05-71 450DLC Excavator Operation and Tests 062608 PN=709 Theory of Operation 35 36 33 27 34 –UN–12APR06 37 21 35 38 36 TX1006229 34 TX1006229 22 Power Dig Solenoid Valve SG Operation 21—Pilot Oil 33—Flange on the Right Is 35—Valve Function Port 37—Valve Spool 22—Return Oil Larger 36—To Hydraulic Oil Tank 38—Reduced Pilot Oil 27—Power Dig Solenoid Valve 34—From Pilot Filter and SG Pressure Regulating Valve Power Dig Solenoid Valve SG Operation—The pilot oil (38) to the main relief and power dig valve. power dig solenoid valve SG (27) is a proportional Because the flange on the right is larger (33) than the solenoid valve type.
The solenoid valve is activated by flange on the left, the spool is pushed to the right an electrical signal from the MCF. against the magnetic force as the electrical signal to the solenoid increases. When the reduced pilot oil When de-energized, the spool (37) is pushed to the pressure becomes equal to or greater than the right by a spring. The valve function port (35) is then magnetic force, the spool is pushed to the right, connected to the hydraulic oil tank (36). closing the passage.
The spool is moving constantly to maintain the reduced pilot oil pressure to the main When energized, the magnetic force shifts the spool relief and power dig valve in response to the electrical left against the spring. Pilot oil (21) flows past the signal to the solenoid. spool flange and out the valve function port as reduced LD30992,000025C –19–13APR06–6/6 9025 05 71