John Deere 450DLC — Boom Flow Rate Circuit Operation

TM2361 (24JUN08) 9025-05-89 450DLC Excavator Operation and Tests 062608 PN=727 Theory of Operation Flow Rate Control Valve Activated—Pilot oil (182) 180 SUPPLY OIL pressure from boom flow rate solenoid valve (Y22) will 168 shift the boom flow rate control valve—switch valve (97). 182 PILOT OIL As high pressure supply oil (180) from pump 1 (15) pushes the piston in the boom flow rate control valve— 184 RETURN OIL poppet valve (98). Back pressure in the poppet valve 103 increases and will force the valve closed, as a result the poppet valve restricts flow rate to boom 1 spool (99) and 104 126 102 high pressure supply oil is supplied to other actuators that have higher load pressure.

2 99 Y22—From Boom Flow Rate Solenoid Valve –UN–20MAR06 2—Boom Down 98 3—Poppet—Check Valve 4—Boom Flow Rate Control Valve—Check Valve 97 15—From Pump 1 97—Boom Flow Rate Control Valve—Switch Valve TX1005028 98—Boom Flow Rate Control Valve—Poppet Valve 99—Boom 1 Spool TX1005028 Y22 15 102—Boom Reduced Leakage Valve—Switch Valve Flow Rate Control Valve Activated 103—Boom Reduced Leakage Valve—Check Valve 104—Check Valve 126—To Boom 2 Spool 168—Boom Cylinder (2 used) 168—Boom Cylinder (2 used) 180—Supply Oil 182—Pilot Oil 184—Return or Pressure-Free Oil Continued on next page LD30992,0000263 –19–26APR06–4/7 9025 05 89