TM2361 (24JUN08) 9025-15-10 450DLC Excavator Operation and Tests 062608 PN=760 Diagnostic Information 7 Main Relief and Power Digging Valve Setting Check Key on, use monitor service menu to display Pump 1 and Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: To test with remote gauge, Perform Main Relief and Power Digging Valve Test and Adjustment. (Group 9025-25.) Run engine at fast idle and operate boom raise function. Observe pump 1 and 2 delivery pressure when boom raise is held over relief. Are both pumps delivery pressure in 30.4—32.9 MPa range? YES: Go to Pump Regulator Check NO: Replace main relief and power digging valve.
See Control Valve Disassemble and Assemble. (Group 3360.) – – –1/1 8 Pump Regulator Check Key on, use monitor service menu to display Target Pump 1 and Pump 2 Flow Rate. See Monitor Service Menu Operation. (Group 9015-16.) Check if pumps are stuck at maximum displacement. Observe flow rate on each pump as boom raise function is operated, slow to fast speed Do pump 1 or pump 2 target flow rates start low and increase with boom speed? YES: Diagnostic procedure complete. NO: Repair or replace pump 1 or pump 2 regulator. Perform Pump Regulator Test and Adjustment— Minimum Flow.
(Group 9025-25.) – – –1/1 Diagnose Fan Drive Hydraulic System Malfunctions MR50960,00000F3 –19–26APR06–1/1 9025 15 10 Cooling Fan Remains At Maximum Speed Diagnostic Procedure IMPORTANT: If all hydraulic function speed are slow, perform All Hydraulic Functions Slow Diagnostic Procedure (Group 9025-15.) instead of this procedure. NOTE: If the sensor controlling the fan pump flow rate control is disconnect or failed, fan speed defaults to maximum speed. – – –1/1