TM2361 (24JUN08) 9025-15-42 450DLC Excavator Operation and Tests 062608 PN=792 Diagnostic Information 1 Actuating Pilot Pressure Check Key on, use monitor service menu to display Travel Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function. Perform Control Valve Spool Actuating Pilot Pressure Test. (Group 9025-25.) Run engine at fast idle and raise problem track off ground. Observe pressure when operating lever full travel. Is pilot pressure above 3.70 MPa? YES: Go to Circuit Relief Valve Check. NO:
If pressure is low, adjust or replace valve. Perform Pilot Pressure Regulating Valve Test and Adjustment. (Group 9025-25.) – – –1/1 2 Circuit Relief Valve Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and operate each track over relief. Record pressure. Do all circuit relief valve above 30.4 MPa? YES: Diagnostic procedure complete. NO: Adjust or repair circuit relief. Perform Circuit Relief Valve Test and Adjustment.
(Group 9025-25.) – – –1/1 One Track Does Not Rotate Or Moves Slowly Diagnostic Procedure – – –1/1 9025 15 42 1 Track Sag Check Check track sag. See Check and Adjust Track Sag. (Operator’s Manual.) Is track sag within specification on both tracks? YES: Go to Actuating Pilot Pressure Check. NO: Adjust track sag. – – –1/1 2 Actuating Pilot Pressure Check Key on, use monitor service menu to display Travel Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function. Perform Control Valve Spool Actuating Pilot Pressure Test.
(Group 9025-25.) Run engine at fast idle and raise problem track off ground. Observe pressure when operating lever full travel. Is pilot pressure above 3.70 MPa? YES: Go to Circuit Relief Valve Check. NO: If pressure is low, adjust or replace valve. Perform Pilot Pressure Regulating Valve Test and Adjustment. (Group 9025-25.) – – –1/1