24. SERVICE PROCEDURE 10. When the water is completely clean, stop the engine, close drain valve , wrap the drain plug with seal tape, then close drain plug 11. Replace the corrosion resistor cartridge and open valves . For details of replacement of the corrosion resistor, see "24.8 EVERY 1000 HOURS SERVICE " 12. Install the undercover. 13. Add cooling water until it overflows from the water filler. 14. To remove the air in the cooling water, run for five minutes at low idling, then for another five minutes at high idling. When doing this, leave radiator cap off. 15.
After draining off the cooling water of reserve tank , clean the in- side of the reserve tank and refill the water between FULL and LOW level. 16. Stop the engine, wait for about three minutes, add cooling water up to near the radiator water filler port, then tighten cap . PC130/150LGP-6K ENG 3-30