VHMS - Section 60 10/11 OM6011 Page 60-6 CALIBRATING PLM Perform calibrations when: 3. With the service meter/odometer value dis- played on character display (3), press the ( ) portion of mode select switch (1) to switch to the operation information display. the machine is received once every month when the suspension cylinder oil or nitrogen charge has been adjusted 4. Press the (>) portion of mode select switch (2) until the PLM display is reached. when a suspension pressure sensor has been replaced when the machine has been modified and the Empty Vehicle Weight (EVW) has changed more than 100 kg (221 lb) 5. Press the ( ) portion of mode select switch (1) to display CALIBRATION.
Then, press the ( ) again. The CALIBRATION display will flash. Empty the body before calibration. Lower the body completely onto the frame. Place the hoist control in the FLOAT position. Ensure no existing fault codes are present before calibration. During calibration, operate the truck on a flat road surface. Travel in a straight line and main- tain a speed of 10 km/h (6 mph). 6. Drive the machine at a speed of 10 km/h (6 mph). When the travel speed becomes stable, press the ( ) portion of mode select switch (1) to display CALIBRATION. The CALIBRATION display will flash two or three times, and then the display will change to the following. NOTE:
To cancel, press the ( ) portion of mode select switch (1). The display will return to the service meter/odometer. 1. Operate the machine. 2. With the engine on, move the shift lever to the N position and stop the engine.