Cummins — HG190, HG220 Engine Manual

www.changlin.com.cn Installing 10mm NOTE: Make sure the acorn nut is tightened to be snug on the fuel shutoff solenoid shaft (Synchro-start only). Install the new fuel shutoff solenoid to the bracket and connect the wires. Make sure the wiring harness on the trombetta solenoid is installed in the 6: 00 o'clock position. Torque Value: 10N-m [84 in-lb] 1. Synchro-start 2. Trombetta 3. Direct Link Activate the switch and check the plunger travel. 1. Synchro-start 2. Trombetta A=86.6 mm [3.4 in] A=91.4 mm [3.6 in] B=60.2 mm [2.4 in] B=63.5 mm [2.5 in] 3. direct Link B=117.1 mm [4.61 in] The plunger must be retracted when the fuel shutoff solenoid is activated to the RUN position"B".

The fuel shutoff solenoid must operate without binding. RQVK Governor Fuel Shutoff Solenoid Removing and Installing 8 mm Remove the hitch pin clip, the mounting capscrews and the fuel shutoff solenoid. Install the new solenoid in reverse order of removal and connect the wires. Torque Value: 10N'm [84 in-lb] 109 / 149 pages