beko SLER 30530 SS — Connection to the main supply

fornia to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and re- quires businesses to warn of potential exposure to such substances. IMPORTANT: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. The fiberglas insulation in self-clean ovens gives off a very small amount of carbon monoxide, benzene, formaldehyde and toluene during the cleaning cycle. Exposure can be minimized by venting with an open window or using ventilation fan or hood. Connection to the main supply IMPORTANT:

Electrical installation should comply with national and local codes. IMPORTANT: This appliance must be grounded! WARNING Avoid fire hazard or electrical shock. Do not use an adapter plug, an extension cord, or remove grounding prong from electrical power cord , have a qualified electrician install an outlet near the appliance. Failure to follow this warning can cause serious injury, fire or death. WARNING Risk of Electric Shock or Fire. Grounding through the neutral conductor is prohibited for new branch circuit installations (1996 NEC), mobile homes, and recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor.

Before starting any work the electrical installation, the electrical power to the range must be shut off while line connections are being made. Failure to follow these instructions can result in death, fire, or electrical shock. Provide Electrical connection Install the junction box under the cabinet and run 120/240 or 120/208 Volt, AC wire from the main 22/EN circuit panel. DO NOT connect the wire to the circuit panel at this time. Electrical requirements This appliance must be supplied with the proper voltage and frequency and connected to an individ- ual, properly grounded branch circuit, protected by a circuit breaker or fuse. A circuit breaker or fuse is required by your appliance.

The circuit breaker or fuse amperage recommended for your appliance is 40A or 50A. Observe all governing codes and local ordin- ances A 3 wire or 4 wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (red and black wires). A time-delay fuse or circuit breaker is recommended. DO NOT fuse neutral (white wire). NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI/ NFPA No. 70-latest edition. IMPORTANT: This appliance must be properly grounded to avoid shock hazard!

Our company shall not held responsible for any damage caused by using the appliance without grounded receptacle. This range must be electrically grounded in accordance with local codes, or in their absence, with the National Electrical Code ANSI/NFPA No. 70-latest edition in United States. Installation should be made by a Licensed elec- trician. WARNING: Risk of electric shock, short circuit or fire by damage of the main power supply! The main power supply lead must not be clamped, bent or trapped or come into contact with hot parts of the appliance. If the main power cable is damaged, it must be replaced by a qualified electrician.

The main power supply lead must not be clamped, bent or trapped or come into contact with hot parts of the appliance. If the main power cable is damaged, it must be replaced by a qualified electrician. This range may be connected by means of perma- nent "hard wiring" (flexible armored or nonmetallic