CANopen Technical Guide | ASDA-A2 U: N/A Please note: 1. For ASDA-A2-M model, Y-bit is available, but X-bit is invalid. 2. For ASDA-A2-F model, X-bit is always be 1. P3-11 Operation Related Section: N/A Interface: Keypad / Software Communication Default: 0x0000 Control Mode: CANopen Unit: N/A Range: refer to the description of Settings Data Size: 16-bit Display Format: Hexadecimal Settings: X=0 : don’t save parameters in EEPROM X=1: save parameters in EEPROM by PDO writing Y: N/A Z: N/A U: N/A Please note: 1. This parameter is only available for ASDA-A2 -M and -F models. 2. When X=1, continuously PDO writing parameters may shorten EEPROM’s lifespan. P3-12 Operation Interface:
Keypad / Software Communication Related Section: N/A Default: 0x0000 Control Mode: CANopen Unit: 0x0000 ~ 0x0111 Range: refer to the description of Settings Revision Sep, 2012 12 Address: 0316H CANOP CANopen saving options 0317H Display U Z Y X Function N/A N/A N/A Options of saving parameters in EEPROM Range N/A N/A 0 ~ F 0 ~ 1 Address: 0318H QSTPO CANopen Quick Stop Settings 0319H