Delta DVP-ES3 — 6.3.2 Explanation of Data Conversion Instructions

Chapter 6 Applied Instructions Example When M0 is ON, the instruction converts the single-precision floating-point number in (D1, D0) into the decimal floating-point number, and stores the conversion result in (D3, D2). Binary floating-point number Real number: 23 bits; Exponent: 8 bits; sign: 1 bit Exponent Real number [D2] 10 X [D3] Decimal floating-point number Mathem atical form Additional remarks If the value in S exceeds the range of values that can be represented by the floating-point numbers, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#2013. 6_ 6-101 D 1 D 0 D 3 D 2