Delta DVP-ES3 — 2.2.8 Refresh Time for Special Auxiliary Relays

Chapter 2 Devices 2_ 2-43 Special auxiliary Refresh time relay SM612–SM613 You set the flag to ON or OFF. SM614 The flag is refreshed when the instruction is executed. SM615–SM617 You set the flag to ON or OFF. SM618 The flag is refreshed when the instruction is executed. SM619 The flag is refreshed when the EI or DI instruction is executed. SM620 The flag is refreshed when the CMPT instruction is executed. SM621–SM686 You set the flag to ON or OFF. SM687 The flag is refreshed when the RAMP instruction is executed. SM688 The flag is refreshed when the INCD instruction is executed. SM690–SM691 You set the flag to ON or OFF. SM692 The flag is refreshed when the HKY instruction is executed.

SM693 The flag is refreshed when the SEGL instruction is executed. SM694 The flag is refreshed when the DSW instruction is executed. SM695 You set the flag to ON or OFF. SM749 The system is refreshed at power-on after the data exchange parameters are downloaded. SM750–SM783 After the data exchange parameters are downloaded, you set the flag to ON or OFF. SM784–SM847 The flag is ON when the system is refreshed. SM861 The system is refreshed at power-on after the data exchange parameters are downloaded. SM862–SM895 After the parameters of data exchange are downloaded, you set the flag to ON or OFF. SM896–SM959 The flag is ON, when the system is refreshed automatically.

SM976-SM990 The flag is ON, when the system is refreshed automatically. SM1000 You set the flag to ON and after saving, the system sets the flag to OFF. SM1006 You set the flag to ON or OFF. SM1008–SM1015 You set the flag to ON or OFF. SM1016–SM1031 The flag is ON, when the system is refreshed automatically. SM1001 ON: the Ethernet connection is active. OFF: the Ethernet connection is not active. SM1090 ON: the TCP connection is busy. SM1091 ON: the UDP connection is busy. SM1100 The flag is refreshed when API 2200-API 2210 is executed or the network cable is reconnected. SM1106 ON: the PHY initialization fails. SM1107 ON:

the IP address, the netmask address, and the gateway address are set incorrectly. SM1109 ON: the socket function is enabled and the same port is used. SM1110 ON: the IP filter of AS-FEN02 is set incorrectly. SM1111 You set the flag to ON or OFF. SM1113 ON: there is a server error. SM1116 ON: the trigger of the PLC parameter is enabled. SM1117 ON: the trigger of the PLC parameter is triggered. SM1119 ON: the trigger is enabled and the last mail has been sent successfully. SM1120 ON: the trigger is enabled and the last mail has been sent with an error. SM1122–SM1123 ON: the trigger is enabled and there is an SMTP server response timeout. SM1124 ON:

the trigger is enabled and the size of the attachment exceeds the limit. SM1125 ON: the trigger is enabled and the attachment is not found. SM1126–SM1127 ON: the trigger of the PLC parameter is enabled. SM1129 ON: the trigger is enabled and the last mail has been sent successfully.