DVP-ES3 Series Programming Manual The following table lists the settings for the device D . When M0 is ON, M20 is ON from 18:00 to 8:00 the next day from Monday to Friday and for other times the M20 is OFF. Example 3 Set a working time from 08:00 to 12:00 and from 14:00 to 17:30 from Monday to Friday. No work on Saturday and Sunday. _6 6-506 Start working time Stop working time Day Start Hour Start Minute Stop Hour Stop Minute Sunday D0 24 D10 00 D20 24 D30 00 Monday D1 18 D11 00 D21 08 D31 00 Tuesday D2 18 D12 00 D22 08 D32 00 Wednesday D3 18 D13 00 D23 08 D33 00 Thursday D4 18 D14 00 D24 08 D34 00 Friday D5 18 D15 00 D25 08 D35 00 Saturday D6 24 D16 00 D26 24 D36 00