Mitsubishi — Chapter 6 Application Instructions API 00-49

6 Application Instructions API 00-49 API 14 Operands: S : Source of data D : Destination device Explanations: 1. If S and D are used in device F, only 16-bit instruction is applicable. 2. See the specifications of each model for their range of use. 3. This instruction can be used for phase-reversed output. 4. Reverse the phase (0 → 1, 1 → 0) of all the contents in S and send the contents to D . Given that the content is a constant K, K will be automatically converted into a BIN value. Program Example 1: 1. When X10 = On, b0 ~ b3 in D1 will be phase-reversed and send to Y0 ~ Y3.

X10 b 0 b 1 b 2 b 3 b 15 D1 No data Sending the phase-reversed data DVP-PLC Application Manual 6-25 Mnemonic Operands Function D CML P Compliment Type OP Bit Devices Word Devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F CML, CMLP: 5 steps DCML, DCMLP: 9 steps S * * * * * * * * * * * D * * * * * * * * PULSE 16-bit 32-bit EH3 SV2 EH3 EH3 ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV SV2 SV2 0 CML D1 K1Y0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Symbol bit (0=positive, 1=negative) 0 1 0 1