EA180 Series Servo Drive Users Manual 7.2.13 P8 group - extended function parameters 90 Unit Appli Com mu.A ddr.

Para Data Initial Attri Function Parameter range cable meter type value bute mode P7-44 Map SA 8 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 072C H P7-45 Map DA 8 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 072D H P7-46 Map SA 9 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 072E H P7-47 Map DA 9 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 072F H P7-48 Map SA 10 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 0730 H P7-49 Map DA 10 for Modbus communication 0000H ~ FFFFH U16 FFFF H - PST 〇 0731 H Applica Attr Com Para Data Initial value Uni Function Parameter range ble ibut mu. meter type t mode e Addr.

P8-00 JOG speed 0~10000 U16 100 rpm P S T 〇 0800H P8-01 JOG acc/dec time 1~65535 U16 200 ms P S T 〇 0801H P8-02 Auto tuning torque identified by offline inertia 10~200 U16 50 % P S T 〇 0802H P8-03 Maximum number of revolutions identified by offline inertia 1~20 U16 10 rev P S T 〇 0803H P8-04 Reserved P8-05 Maximum revolution number of absolute encoder 1~32767 U16 32767 rev P S T 〇 0805H P8-06 Absolute encoder use method selection 0: Used as an incremental encoder 1: Used as an absolute encoder U16 0 - P S T ● 0806H P8-07 Fan control 0: Fan runs when servo enabled or alarm/warning occurs 1: Fan runs when power-on 2:

Fan runs according to drive temperature U16 0 - P S T 〇 0807H P8-08 Drive overload warning threshold 20~100 U16 80 % P S T 〇 0808H P8-09 Motor overload warning threshold 20~100 U16 80 % P S T 〇 0809H P8-10 Braking resistor resistance setting 20~30000 U16 50 Ω P S T 〇 080A H P8-11 Braking resistor power setting 10~30000 U16 100 W P S T 〇 080B H P8-12 Brake duty ratio 0~100 U16 100 % P S T 〇 080C H P8-13 Braking resistor derating percentage 1~100 U16 40 % P S T ● 080D H P8-14 Minimum load for motor stall judgment 10.0~250.0 U16 150.0 % P S T 〇 080EH P8-15 Speed for motor stall judgment 0~500 (0:

Stall judgment function disabled) U16 0 rpm P S T 〇 080FH P8-16 Time for motor stall judgment 10~3000 U16 100 ms P S T 〇 0810H P8-17 Torque limit for motor 0.0~150.0 U16 100.0 % P S T 〇 0811H