Parameter functions: Set the breadth of the 1st notch filter. A greater value indicates greater suppression near the central frequency. Parameter functions: Notching depth of the first notch filter. A smaller value indicates greater suppression Parameter functions: Set the second notch filter Parameter functions:
Set the third notch filter 135 Technical Manual for EA190 Series Servo Driver V100 3 Unit - Time of taking effect Taking effect upon power-on again Setting range 0~20 Data size 16bit Control mode P S T P5-04 1st notching depth Initial value 0 Communication address 0504H Unit dB Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P5-05 2nd notching frequency Initial value 5000 Communication address 0505H Unit Hz Time of taking effect Taking effect upon power-on again Setting range 50~5000 Data size 16bit Control mode P S T P5-06 2nd notching width Initial value 2 Communication address 0506H Unit - Time of taking effect Taking effect upon power-on again Setting range 0~20 Data size 16bit Control mode P S T P5-07 2nd notching depth Initial value 0 Communication address 0507H Unit dB Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P5-08 3rd notching frequency Initial value 5000 Communication address 0508H Unit Hz Time of taking effect Taking effect upon power-on again Setting range 50~5000 Data size 16bit Control mode P S T P5-09 3rd notching width Initial value 2 Communication address 0509H Unit - Time of taking effect Taking effect upon power-on again Setting range 0~20 Data size 16bit Control mode P S T P5-10 3rd notching depth Initial value 0 Communication address 050AH Unit dB Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P5-11 4th notching frequency Initial value 5000 Communication address 050BH Unit Hz Time of taking effect Taking effect upon power-on again