86 Technical Manual for EA190 Series Servo Driver V100 command via communication 0: Received data is returned upon receipt of a write command 1: Received data is not returned upon receipt of a write command P7-05 Address selection upon Modbus communication 0: Address + 8000H stored 1: Address + 8000H not stored U16 1 - P S T 〇 - P7-06 Reserved P7-07 Reserved P7-08 Reserved P7-09 Status sequence setting for high 32-bit function code upon Modbus communication 0: For both read and write, the low 16 bits are before the high 16 bits 1: For both read and write, the high 16 bits are before the low 16 bits 2:
For read, the low 16 bits are before the high 16 bits; for write, the high 16 bits are before the low 16 bits 3: For read, the high 16 bits are before the low 16 bits; for write, the low 16 bits are before the high 16 bits U16 0 - PST 〇 0709H P7-10~P7-29 Reserved P7-30 Source address 1 of Modbus communication mapping 0000H~FFFFH U16 FFFFH - PST 〇 071EH P7-31 Target address 1 of Modbus communication mapping 0000H~FFFFH U16 FFFFH - PST 〇 071FH P7-32 Source address 2 of Modbus communication mapping 0000H~FFFFH U16 FFFFH - PST 〇 0720H P7-33 Target address 2 of Modbus communication mapping 0000H~FFFFH U16 FFFFH - PST 〇 0721H