sinee — EA350 User Manual

Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Parameter functions: Set the central frequency of the first notch filter. When it is set to 5000, the notch filter is inactive. Parameter functions: Set the breadth of the 1st notch filter. A greater value indicates greater suppression near the central frequency. Parameter functions: Notching depth of the first notch filter.

A smaller value indicates greater suppression 165 range P5-03 1st notching width Initial value 2 Communication address 0503H Unit - Time of taking effect Taking effect upon power-on again Setting range 0~20 Data size 16bit Control mode P S T P5-04 1st notching depth Initial value 0 Communication address 0504H Unit dB Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P5-05 2nd notching frequency Initial value 5000 Communication address 0505H Unit Hz Time of taking effect Taking effect upon power-on again Setting range 50~5000 Data size 16bit Control mode P S T