sinee — EA350 User Manual

Technical Manual for EA350 Analog Pulse Type Servo Driver V101  If the ORPG signal is valid upon start of homing, the servo will run reversely at the speed of Pb-04 to search the target zero position. Pb-02 = 8 : Target zero position: First Z pulse following the ORPG rising edge Deceleration point: Origin switch (ORPG)  If the ORPG signal is invalid upon start of homing, the servo will run forward at the speed of Pb-03:

◼ If no signal of the forward limit switch P-OT is received, the servo will decelerate to stop when it receives an ORPG rising edge signal; then it will run reversely at the speed of Pb-04 until it receives an ORPG falling edge and then starts to run forward to search the target zero position.

 If a signal of the forward limit switch P-OT is received, the servo will automatically run in the reverse direction at the speed of Pb-03; when it receives an ORPG rising edge signal, it will start to decelerate; after it decelerates to the speed of Pb-04, it will continue running at this speed until it receives an ORPG falling edge and then starts to run reversely at the speed of Pb-04; when it comes to the target zero position, it will stop running  If the ORPG signal is valid upon start of homing, the servo will run reversely at the speed of Pb-04; when it receives an ORPG falling edge, it will start to decelerate to stop; then it will run forward at the speed of Pb-04 to search the target zero position.

227