sinee — EA350 User Manual

Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Command code 0x10: Rewrite multiple continuous function codes of the servo driver Command code 0x08: Line diagnosis Note: Command code 0x08 is only used to check whether the line is connected. 10.5 Description of the protocol format 10.5.1 Address code Servo driver slave address. Setting range 1-247. 10.5.2 Function code 10.5.3 Register address distribution Note: Frequent writing of parameters required to be frequently written to EEPROM may cause damage to EEPROM due to the limited read/write life span of the EEPROM (about 1 million times). 239 Details of the ADU part Number of bytes Scope Request sent by the host:

Slave address 1 0x00-0xFEH Command code 1 0x10 Starting address of register 2 0x0000-0xFFFF Number of registers 2 0x0000-0x0020 Bytes of register content 1 2 * number of registers Register content 2 * number of registers CRC check 2 Slave acknowledgement: Slave address 1 Address of the unit Command code 1 0x10 Starting address of register 2 0x0000-0xFFFF Number of registers 2 0x0000-0x0020 CRC check 2 Details of the ADU part Number of bytes Scope Request sent by the host: Slave address 1 0x00-0xFEH Command code 1 0x08 Sub-function code 2 0x0000 Data 2 0x0000-0xFFFF CRC check 2 Slave acknowledgement:

Slave address 1 Address of the unit Command code 1 0x08 Sub-function code 2 0x0000 Data 2 0x0000-0xFFFF CRC check 2 Function code Function 03H Read a function code of the servo driver 06H Write a single function code of the servo driver (this operation is not intended for a 32-bit function code) 10H Write multiple continuous function codes of the servo driver (For a 32-bit function code, use 10H for operation, with one function code occupying 2 consecutive addresses) 08H Line diagnosis Item Address Space Description 0000H-3FxxH When P7-04=0 and P7-05=1, this address segment corresponds to the EEPROM address of the driver; parameters written to these addresses will be saved. For example:

The EEPROM address corresponding to P2-01 is 0201H (when P7-04=0 and P7-05=1) Function parameter 8000H-BFxxH If it is required to frequently modify the parameters, content of the RAM register shall be modified; when P7-04=0 and P7-05=1, the function parameter address shall be defined as +8000H For example:

The RAM register address corresponding to P2-01 is 8201H (when P7-04=0 and P7-05=1) address Function Parameter MODBUS communication address P7-04 P7-05 0000H~3FxxH (0000H~3FxxH)+8000H 0 1 Write to EEPROM, and save Write to RAM, without saving 0 0 Write to RAM, without saving Write to EEPROM, and save 1 1 Write to RAM, without saving Write to RAM, without saving 1 0 Write to RAM, without saving Write to RAM, without saving