electrolux P6000 (Nexus) Series — 352317en

9.12.2 Rear cabinet shell a. Remove the top b. Remove the screws which secure the shell to the base and to the control panel support c. Remove the screw which secures the fan to the shell (86) 9.12.3 Motor-Fan assembly a. Remove the rear cabinet shell b. Remove the screw which secures the fan to the control panel support (87) c. Detach the fan from the heating element casing: Ц Standard version: if present, remove the seal retaining clamp (88) and fold back the seal on the coupling between the fan and the heating elements (89) Ц High Performance version: remove the screw from the heating element casing (90) d. Detach the fan from the drying condenser and from the cross- member (91) e.

Detach the wiring connector from the motor and remove the fan assembly Re-assembly: For the "High Performance" version, replace the sealing ring (OR) between the heating element casing and the fan; replace the fan assembly on the condenser, attaching to the cross-member; close the anchor tabs using pliers (92), then fully tighten the screw. 9.12.4 Motor / Fan a. Remove the fan assembly b. Detach the drive belt from the pulleys c. Remove the three screws and separate the motor from the fan (93) SOI/DT 2002-05 eb 115 599 35 23-17