electrolux EWM10 — 599735408en

Current leak to the ground ѓ Earth leakage between heating element and earth. A.D.L. 10 / 2010 20/26 Heating element power relay faulty (inconsistency between sensing and relay status) ѓ Main circuit board faulty. Heating element interrupted ѓ Faulty wiring. ѓ Heating element for washing interrupted (thermal fuse open). ѓ Main circuit board faulty. Heating relay sensing faulty ѓ Main circuit board faulty. Description Possible fault ѓ Faulty wiring. ѓ Earth leakage between heating element and earth. ѓ Main circuit board faulty. ѓ Faulty wiring. ѓ NTC probe for wash cycle faulty. ѓ Heating element faulty. ѓ Main circuit board faulty. ѓ Faulty wiring. ѓ NTC probe for wash cycle faulty.

ѓ Heating element faulty. ѓ Main circuit board faulty. Overheating during washing phase (temperature higher than 88°C for more than 5 min.) Insufficient heating during the washing phase Heating element power relay faulty (inconsistency between sensing and relay status) ALARM CODE E61 E62 E66 E68 E69 E6A E6H ALARM CODE Action Description Possible fault Reset Machine status E61 Insufficient heating during the washing phase ƒ Faulty wiring. ƒ NTC probe for wash cycle faulty. ƒ Heating element faulty. ƒ Main circuit board faulty. The heating phase is skipped START/RESET E62 Overheating during washing phase (temperature higher than 88°C for more than 5 min.) ƒ Faulty wiring.

ƒ NTC probe for wash cycle faulty. ƒ Heating element faulty. ƒ Main circuit board faulty. Safety drain cycle. Cycle stops with door open RESET E66 Heating element power relay faulty (inconsistency between sensing and relay status) ƒ Main circuit board faulty. Safety water fill. Cycle stops with door closed. ON/OFF RESET E68 Current leak to the ground ƒ Earth leakage between heating element and earth. The heating phase is skipped START/RESET E69 Heating element interrupted ƒ Faulty wiring. ƒ Heating element for washing interrupted (thermal fuse open). ƒ Main circuit board faulty. ---------------- START ON/OFF RESET E6A Heating relay sensing faulty ƒ Main circuit board faulty.

Cycle stops with door locked RESET E6H Heating element power relay faulty (inconsistency between sensing and relay status) ƒ Faulty wiring. ƒ Earth leakage between heating element and earth. ƒ Main circuit board faulty. Safety water fill Cycle stops with door closed. ON/OFF RESET